The Tranemo 5419 88 is an arc flash jacket in Cantex 1210 fabric (350 g/m²), rated ATPV 11.9 cal/cm² and certified to IEC 61482-2 Class 1. It protects substation and switchroom personnel against arc flash and heat exposure, with sizes XS to XXXL in navy.
Tranemo 5419 88 Arc Flash Jacket, Class 1, 11.9 cal/cm²
The Tranemo 5419 88 is a flame retardant arc flash jacket built for people who work in and around energised switchgear. It carries an ATPV of 11.9 cal/cm² and is certified to IEC 61482-2 Class 1, so it sits comfortably in the PPE selection for most MV and LV switching tasks where the incident energy calculation supports a Class 1 garment. Combined with Cantex underwear, the system approves for IEC 61482-2 Class 2, worth knowing if your site labels sit above the single-layer rating.
Fabric and certification
The jacket is made from Cantex 1210 at 350 g/m², with a limiting oxygen index (LOI) of 34.3%. A substantial fabric, chosen for durability as much as protection. The certification set is broad, which makes the jacket useful beyond pure arc flash work:
- EN ISO 11612 A1+A2 B1 C1 E3 F1, heat and flame, including molten metal splash (E3)
- IEC 61482-2 Class 1, thermal hazards of an electric arc, ATPV 11.9 cal/cm²
- EN 1149-5, electrostatic dissipative properties
- EN ISO 11611 Class 1 A1+A2, welding and allied processes
- EN 13034 type PB[6], limited protection against liquid chemicals
Unsure how arc ratings map to your site study? Our guide on what arc flash is and the wider arc flash protection range are good starting points.
Practical details
A working jacket, not a showpiece. Concealed front zip, contrast stitching, and a sensible pocket layout: chest pockets with flaps and a concealed keyring holder, a zipped mobile phone pocket, flapped side and sleeve pockets, and two large inside pockets. The extended back, adjustable waistband and cuffs, and actionback give free movement when reaching into a panel or racking a breaker.
| Attribute | Detail |
|---|---|
| Arc rating | ATPV 11.9 cal/cm², IEC 61482-2 Class 1 (Class 2 with Cantex underwear) |
| Fabric | Cantex 1210, 350 g/m², LOI 34.3% |
| Sizes | XS to XXXL |
| Colour | Navy (03) |
FAQs
Is this jacket suitable for a 10 kV switchroom?
That depends on your incident energy study, not the voltage alone. At 11.9 cal/cm² ATPV and Class 1, the jacket covers many MV switching tasks, but you must match PPE to the calculated incident energy on the equipment label. Layered with Cantex underwear it approves for Class 2.
Can it be worn for welding work?
Yes. The jacket is certified to EN ISO 11611 Class 1 A1+A2 for welding and allied processes, alongside its arc flash and heat and flame ratings, so it suits mixed maintenance duties where both hazards appear.
Not exactly what you are looking for? Contact us with your exact requirements, we’re happy to help.