Fristads 2042 FBPA arc rated hi-vis trousers in yellow/navy, art. no. 101046. Class 1 arc rating to the EN 61482-1-2 box test, with an open-arc ATPV of 13 cal/cm² (HAF 81%). A 65% flame-retardant cotton blend at 350 g/m². For substation and switchroom staff needing arc rated, high-visibility work trousers.
Fristads 2042 FBPA Arc Rated Hi-Vis Trousers
The Fristads 2042 FBPA (art. no. 101046) is an arc rated, high-visibility work trouser for substation and switchroom tasks where an arc flash hazard has been identified. It is certified to the EN 61482-1-2 box test at Class 1, with an open-arc ATPV of 13 cal/cm² (HAF 81%) under EN 61482-1-1. The rating your site needs should come from an arc flash study; our wider arc flash protection range covers the matching jackets, suits and accessories.
Arc and flame ratings
Two arc test methods appear on the manufacturer datasheet: the box test (EN 61482-1-2, Class 1) and the open-arc ATPV method (EN 61482-1-1, 13 cal/cm²). The trousers also carry EN ISO 11612 (heat and flame), EN ISO 11611 (welding), EN 1149-5 (electrostatic) and EN ISO 20471 high visibility, reaching class 2 in all sizes except C44, which achieves class 1. Background on the test methods sits in our arc flash information pages.
| Standard | Result |
|---|---|
| EN 61482-1-2 (box test) | Class 1 |
| EN 61482-1-1 (open arc) | ATPV 13 cal/cm², HAF 81% |
| EN ISO 11612 | A1 A2 B1 C1 E2 F1 |
| EN ISO 11611 | A1 A2 Class 1 |
| EN 1149-5 | Electrostatic, compliant |
| EN ISO 20471 (high visibility) | Class 2 (class 1 in size C44) |
| ISO 15797 | Leasing laundry-tested |
Material, pockets and knees
The fabric is Fristads FlamTech, 65% FR cotton, 34% polyester and 1% antistatic fibres at 350 g/m². Sizes run Regular C44-C64, Tall C146-C156 and Short D84-D120, with the short sizes listed as a made-to-order solution.
- 2 front pockets and 2 back pockets with flaps
- Leg pocket with flap, phone pocket with flap and velcro fastening, plus concealed ID-card holder
- Folding rule pocket
- Pre-shaped knees with height-adjustable knee-pad pockets
FAQs
What does Class 1 to EN 61482-1-2 mean?
The EN 61482-1-2 box test exposes fabric to a controlled arc, Class 1 tested at 4 kA and Class 2 at 7 kA. The open-arc ATPV of 13 cal/cm² is a separate measure, and it is the figure most sites use when matching PPE to an incident-energy study.
Is 13 cal/cm² enough for our switchrooms?
That depends on the calculated incident energy at each location. Many MV switching tasks stay below 13 cal/cm², but the rating must meet or exceed the figure on your arc flash label or study. If it does not, consider a switching suit from the arc flash protection range instead.
Not exactly what you are looking for? Contact us with your exact requirements, we’re happy to help.